Manufacturer and supplier of cables, wires & cables accessories

Shenzhen Chengtiantai Cable Industry Developemnt Ltd., co

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsXLPE Insulated Power Cable

IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed

Certification
Good quality Copper Coaxial Cable for sales
Good quality Copper Coaxial Cable for sales
Fast response, exact delivery dates and their ability to help with urgent or large orders makes chengtiantai cable an excellent company to work with.

—— Antonio Esteves (Brazil)

We appreciate the support extended by Shenzhen Chengtiantai Cable in terms of delivery for many of our orders.

—— Budi Ramli ( Indonesia)

I find the management team at CTT Cables proactive and easy to deal with.

—— Christopher Wong (Malaysia)

CTT cable is a reliable, honest helpful and trustworthy supplier and one which we would have no hesitation recommending to any prospective company.

—— Dale (South Africa)

I'm Online Chat Now

IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed

China IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed supplier
IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed supplier IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed supplier

Large Image :  IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed

Product Details:

Place of Origin: Shenzhen City, Mainland China
Brand Name: Chengtiantai cable
Certification: CE, CB
Model Number: YJV

Payment & Shipping Terms:

Minimum Order Quantity: 500 m
Price: On Request
Packaging Details: Steel wooden Drum
Delivery Time: 15 working days after payments
Payment Terms: L/C, T/T
Contact Now
Detailed Product Description
Rated Voltage: 0.6 / 1kV Conductor: Bear Copper
No. Of Cores: 3 Cores Insulation: XLPE Compound
Armoured Type: Unarmoured Sheath: PVC Compound

 

  IEC 60502-1 Cables

 

600/1000V, XLPE Insulated Cables according to IEC 60502-1

 

Applications

 

These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.

 

Construction

1. Conductors

------------------------------------------------------------------------------------------------------

The conductors shall be either of Class 1 or Class 2 of plain or metal-coated annealed copper or of plain aluminium or aluminium alloy, or of Class 5 of plain or metal-coated copper in accordance with IEC 60228.
2. Insulation

------------------------------------------------------------------------------------------------------

XLPE material and thickness shall be as per IEC 60502 or BS 5467 rated for 90°C continuous operation.
3. Assembly / Inner Covering

------------------------------------------------------------------------------------------------------

The inner coverings may be extruded or lapped. For cables with circular cores, except cables with more than five cores, a lapped inner covering shall be permitted only if the interstices between the cores are substantially filled. A suitable binder is permitted before application of an extruded inner covering. The material is compatible with the insulating material,The materials used for inner coverings and fillers shall be suitable for the operating temperature of the cable and compatible with the insulating material.For halogen free cables, the inner covering and fillers shall also be halogen free compound.
4. Armour

------------------------------------------------------------------------------------------------------

Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1, or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request.
5. Outer Sheath

------------------------------------------------------------------------------------------------------

Outer sheath shall be of extruded PVC Type ST1/ST2 as per IEC 60502-1, Polyethylene type ST3/ST7, Halogen free compound ST8, Polychloroprene, chlorosulfonated polyethylene or similar polymers, type SE1 are also available on request.
6. Fire Performance of Cable Sheaths

------------------------------------------------------------------------------------------------------

Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22, IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.

 

 

  Physical and Electrical Characteristics:

 

No.cores x
cross-sec.
Insulation
thickness
Sheath
thickness
Nominal
value
Outer Ø
approx.
weight
approx.
Current ratings in air 30℃ Current ratings buried 20℃ maximum DC resistance at 20℃
mm² mm mm mm kg / km A A Ω/km
3×1.5 0.7 1.8 10.1 132 21 28 12.1
3×2.5 0.7 1.8 11.0 171 28 37 7.41
3×4.0 0.7 1.8 12.0 225 37 48 4.61
3×6.0 0.7 1.8 13.1 296 47 61 3.08
3×10 0.7 1.8 15.3 440 64 82 1.83
3×16 0.7 1.8 17.5 638 85 107 1.15
3×25 0.9 1.8 21.0 954 115 138 0.73
3×35 0.9 1.8 23.1 1266 140 165 0.52
3×50 1.0 1.8 23.4 1614 168 198 0.39
3×70 1.1 1.9 27.4 2264 213 242 0.27
3×95 1.1 2.0 30.6 2975 263 290 0.19
3×120 1.2 2.1 34.0 3776 307 330 0.15
3×150 1.4 2.3 38.6 4682 357 371 0.12
3×185 1.6 2.4 43.3 5802 415 418 0.10
3×240 1.7 2.6 48.1 7437 498 485 0.08
3×300 1.8 2.8 52.2 9313 575 548 0.06

 

 

 

INSTALLATION METHOD DETAILS

 

IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed   IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed   IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed   IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed
A1 – Thermally insolated wall (Single-core) A2 – Thermally insolated wall (multi-core) B1 – Apparent electroduct (Single-core) B2 – Apparent electroduct (multi-core)
 
IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed   IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed   IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed   IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed
B1 – Electroduct in brickwork (Single-core)   B1 – Electroduct in brickwork (multi-core)   C – On the wall    C – On the ceiling
             
IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed   IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed   IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed   IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed
C – Non-perforated tray   F – Perforated tray (Single-core)   F – Perforated tray (multi-core)   F –Suspended (Single-core)
             
IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed   IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed   IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed   IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed
E – Suspended (multi-core)   B2 – Construction space   B2 – Construction space   B1 – Electroduct (Single-core)
             
IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed   IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed   IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed   IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed
B2 – Electroduct (Multi-core)   B2 – Closed raceway embedded in floor (multi-core)   B2 – Closed raceway embedded in floor (multi-core)   B1 – Ventilated raceway embedded in floor
             
IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed   IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed        
C – Embedded in the brickwork   D – Buried in additional mechanical protection        

 

 

  Cable Drum Data

 

CABLE DRUMS D1=Flange Diameter(mm) W=Useful Width (mm) D2=Barrel Diameter(mm)
Low Voltage Power Cable 0.6/1 kV 3+2 Core XLPE Insulated, PVC Sheathed, Unarmoured & Armoured to IEC 60502 1000 700 500
1100 700 550
1200 700 600
1400 750 710
1600 900 900
1800 1120 1000
2400 1150 1300

 

 

  RECOMMENDED ORDERING PARAMETERS

   CONTACT

For prompt quotation / supplies please make sure your inquiries and your orders are
securing the following data :

1 - International or Special Standard. (Alternatively, the precise usage of the cable.)
2 - Rated voltage.
3 - Copper or Aluminium conductors.
4 - Size of each conductor.
5 - Insulation material : XLPE or others.
6 - Number and identification of conductors.
7 - Other requirements.
8 - Packing.
9 - Required delivery time.
10 - Required validity.

If this all seems a litle too technical for you, then why not get in touch with us.

 

We look forward to assisting you in identifying the best products for your specific application and to answer any questions you might have.

 

Tel:+86 755 6114 5028
Fax:+86 755 61137976
E-mail : cttcable@hotmail.com
Head office:chengtiantai Industrial Park, Lisonglang community, Gongming office, Guangming district, Shenzhen P.R. China 518106

 

  WARRANTY

 

For a period commencing on the date shipped the Goods to Buyer and continuing for a period of 12 months thereafter.

Contact Details
Shenzhen Chengtiantai Cable Industry Development Co.,Ltd

Contact Person: Mr. Xie

Tel: +8618682219285

Send your inquiry directly to us (0 / 3000)