Four Core Fire Resistant Electrical Wire Cable For Local Energy Distributions

500 M
MOQ
On request
Price
Four Core Fire Resistant Electrical Wire Cable For Local Energy Distributions
Features Gallery Product Description Request A Quote
Features
Specifications
Rated Voltage: 0.6/1 KV
No.of Cores: 4 Cores
Fire Barrrier: Mica-tape
Conductor: Bare Copper
Insulation: XLPE
Sheath: LSZH
High Light:

fire rated electrical cable

,

fire resistant power cable

,

IEC 60502 Fire Resistant Electrical Wire 

Basic Infomation
Place of Origin: Mainland, China
Brand Name: Chengtiantai Cable
Certification: CB, CE
Model Number: WDZ-YJV
Payment & Shipping Terms
Packaging Details: Steel Wooden Drum
Delivery Time: 15 working days
Payment Terms: L/C, T/T
Product Description

Fire resistant cable 4 core 0.6/1 kV Cu-conductor, Mica-tape, XLPE Insulated, LSZH sheathed

 

Applications

These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.
Construction

1. Conductors

The conductors shall be either of Class 1 or Class 2 of plain or metal-coated annealed copper or of plain aluminium or aluminium alloy, or of Class 5 of plain or metal-coated copper in accordance with IEC 60228.
2. Insulation

XLPE material and thickness shall be as per IEC 60502 or BS 5467 rated for 90°C continuous operation.
3. Assembly / Inner Covering

The inner coverings may be extruded or lapped. For cables with circular cores, except cables with more than five cores, a lapped inner covering shall be permitted only if the interstices between the cores are substantially filled. A suitable binder is permitted before application of an extruded inner covering. The material is compatible with the insulating material,The materials used for inner coverings and fillers shall be suitable for the operating temperature of the cable and compatible with the insulating material.For halogen free cables, the inner covering and fillers shall also be halogen free compound.
4. Armour

Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1, or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request.
5. Outer Sheath

Outer sheath shall be of extruded PVC Type ST1/ST2 as per IEC 60502-1, Polyethylene type ST3/ST7, Halogen free compound ST8, Polychloroprene, chlorosulfonated polyethylene or similar polymers, type SE1 are also available on request.
6. Fire Performance of Cable Sheaths

Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22, IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.


Physical and Electrical Characteristics:

 

No.cores x
cross-sec.
Insulation
thickness

Nominal

Sheath
thickness

Outer Ø
approx.
weight
approx.
Current ratings in air 30℃ Current ratings buried 20℃ maximum DC resistance at 20℃
mm² mm mm mm kg / km A A Ω/km
4×4 1.0 1.8 14.9 339 30 38 4.61
4×6 1.0 1.8 16.1 436 38 48 3.08
4×10 1.0 1.8 19.3 669 53 66 1.83
4×16 1.0 1.8 21.8 953 70 86 1.15
4×25 1.2 1.8 26.0 1374 94 112 0.73
4×35 1.2 1.8 28.7 1810 116 135 0.52
4×50 1.4 1.9 29.5 2312 139 161 0.39
4×70 1.4 2.1 33.0 3105 177 202 0.27
4×95 1.6 2.2 38.1 4179 217 240 0.19
4×120 1.6 2.4 41.1 5185 254 274 0.15
4×150 1.8 2.5 45.8 6414 294 309 0.12
4×185 2.0 2.7 50.5 7901 337 346 0.10
4×240 2.2 2.9 55.7 10249 401 403 0.08
4×300 2.4 3.1 63.4 13365 470 459 0.06

 

 

INSTALLATION METHOD DETAILS

 

Four Core Fire Resistant Electrical Wire Cable For Local Energy Distributions 0   Four Core Fire Resistant Electrical Wire Cable For Local Energy Distributions 1   Four Core Fire Resistant Electrical Wire Cable For Local Energy Distributions 2   Four Core Fire Resistant Electrical Wire Cable For Local Energy Distributions 3
A1 – Thermally insolated wall (Single-core) A2 – Thermally insolated wall (multi-core) B1 – Apparent electroduct (Single-core) B2 – Apparent electroduct (multi-core)
 
Four Core Fire Resistant Electrical Wire Cable For Local Energy Distributions 4   Four Core Fire Resistant Electrical Wire Cable For Local Energy Distributions 5   Four Core Fire Resistant Electrical Wire Cable For Local Energy Distributions 6   Four Core Fire Resistant Electrical Wire Cable For Local Energy Distributions 7
B1 – Electroduct in brickwork (Single-core)   B1 – Electroduct in brickwork (multi-core)   C – On the wall    C – On the ceiling
             
Four Core Fire Resistant Electrical Wire Cable For Local Energy Distributions 8   Four Core Fire Resistant Electrical Wire Cable For Local Energy Distributions 9   Four Core Fire Resistant Electrical Wire Cable For Local Energy Distributions 10   Four Core Fire Resistant Electrical Wire Cable For Local Energy Distributions 11
C – Non-perforated tray   F – Perforated tray (Single-core)   F – Perforated tray (multi-core)   F –Suspended (Single-core)
             
Four Core Fire Resistant Electrical Wire Cable For Local Energy Distributions 12   Four Core Fire Resistant Electrical Wire Cable For Local Energy Distributions 13   Four Core Fire Resistant Electrical Wire Cable For Local Energy Distributions 14   Four Core Fire Resistant Electrical Wire Cable For Local Energy Distributions 15
E – Suspended (multi-core)   B2 – Construction space   B2 – Construction space   B1 – Electroduct (Single-core)
             
Four Core Fire Resistant Electrical Wire Cable For Local Energy Distributions 16   Four Core Fire Resistant Electrical Wire Cable For Local Energy Distributions 17   Four Core Fire Resistant Electrical Wire Cable For Local Energy Distributions 18   Four Core Fire Resistant Electrical Wire Cable For Local Energy Distributions 19
B2 – Electroduct (Multi-core)   B2 – Closed raceway embedded in floor (multi-core)   B2 – Closed raceway embedded in floor (multi-core)   B1 – Ventilated raceway embedded in floor
             
Four Core Fire Resistant Electrical Wire Cable For Local Energy Distributions 20   Four Core Fire Resistant Electrical Wire Cable For Local Energy Distributions 21        
C – Embedded in the brickwork   D – Buried in additional mechanical protection        

 

Cable Drum Data

 

CABLE DRUMS D1=Flange Diameter(mm) W=Useful Width (mm) D2=Barrel Diameter(mm)
Low Voltage Power Cable 0.6/1 kV 3+2 Core XLPE Insulated, PVC Sheathed, Unarmoured & Armoured to IEC 60502 1000 700 500
1100 700 550
1200 700 600
1400 750 710
1600 900 900
1800 1120 1000
2400 1150 1300
 

 

 

  RECOMMENDED ORDERING PARAMETERS

  CONTACT

For prompt quotation / supplies please make sure your inquiries and your orders are
securing the following data :

1 - International or Special Standard. (Alternatively, the precise usage of the cable.)
2 - Rated voltage.
3 - Copper or Aluminium conductors.
4 - Size of each conductor.
5 - Insulation material : XLPE or others.
6 - Number and identification of conductors.
7 - Other requirements.
8 - Packing.
9 - Required delivery time.
10 - Required validity.

If this all seems a litle too technical for you, then why not get in touch with us.

 

We look forward to assisting you in identifying the best products for your specific application and to answer any questions you might have.

 

Tel:+86 755 6114 5028
Fax:+86 755 61137976
E-mail : cttcable@hotmail.com
Head office:chengtiantai Industrial Park, Lisonglang community, Gongming office, Guangming district, Shenzhen P.R. China 518106

 

  WARRANTY

 

For a period commencing on the date shipped the Goods to Buyer and continuing for a period of 12 months thereafter.

Recommended Products
Get in touch with us
Contact Person : Annie Chen
Tel : +8613670012325
Fax : 86-755-29886488
Characters Remaining(20/3000)