Manufacturer and supplier of cables, wires & cables accessories

Shenzhen Chengtiantai Cable Industry Developemnt Ltd., co

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsMedium Voltage Power Cables

XLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KV

Certification
Good quality Copper Coaxial Cable for sales
Good quality Copper Coaxial Cable for sales
Fast response, exact delivery dates and their ability to help with urgent or large orders makes chengtiantai cable an excellent company to work with.

—— Antonio Esteves (Brazil)

We appreciate the support extended by Shenzhen Chengtiantai Cable in terms of delivery for many of our orders.

—— Budi Ramli ( Indonesia)

I find the management team at CTT Cables proactive and easy to deal with.

—— Christopher Wong (Malaysia)

CTT cable is a reliable, honest helpful and trustworthy supplier and one which we would have no hesitation recommending to any prospective company.

—— Dale (South Africa)

I'm Online Chat Now

XLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KV

China XLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KV supplier

Large Image :  XLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KV

Product Details:

Place of Origin: Shenzhen, China ( mainland)
Brand Name: Chengtiantai
Certification: CE, CB

Payment & Shipping Terms:

Minimum Order Quantity: 300 m
Price: On Request
Packaging Details: Steel wooden drum
Delivery Time: 7/10 working days
Payment Terms: T/T, L/C
Supply Ability: 20,000 KM per Month
Contact Now
Detailed Product Description
Nominal Voltage: 6-35 KV Insulation: XLPE
No. Of Conductor: Single & 3 Core Sheath: PVC Compound
Conductor Material: Bare Copper Class 2 Manufacturer: Shenzhen Chengtiantai

Medium Voltage Power Cable single core

3.6/6 kV, 6/10 kV, 8.7/15 kV, 12/20 kV, 18/30 kV, 21/35KV, 26/35KV

 

XLPE Insulated, Copper conductor, single core, screened, PVC sheathed

 

The single core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 3.6/6KV to 26/35KV and frequency 50Hz.

 

They are suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries, switchboards and power stations.

 

  STANDER

International:IEC60502-2

National:GB/T 12706.1-2008

  CONSTRUCTION:

1. CONDUCTOR

Bare copper class 2 to IEC 60228, round, multiwire stranded and compact

2. CONDUCTOR SCREEN

Inner semi-conducting coating

3. INSULATION

Core insulation of cross-linked polyethylene (XLPE)

4. INSULATION SCREEN

Outer conductive layer extruded and per-manently welded with the core insulation

Semi-conducting type
– Over the outer semi-conducting layer, a semiconducting tape must be used.

5. METAL SCREEN

copper tapes helically with a minimum thickness of 0,1 mm.

Separator
– Over the screen as well as under outer sheath, a separating layer must be used (e. g. taping).

6. SHEATH

Outer sheath of PVC compound

  ​PHYSICAL PROPERTIES:

Temperature range
– during installation up to -5°C

Operating temperature
– max. +90°C

Short circuit temperature
+250°C (short circuit duration max. 5 s)

Minimum bending radius
– 20 x cable Ø

XLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KV

XLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KV

 

  Nominal /Operating /Testing Voltages

 

Nominal voltage( U0/U) Operating voltage 50 Hz Test voltage(kV/5 min)
3.6/6 kV 7.2 kV 12.5 kV
6/10 kV 12 kV 21 kV
8.7/15 kV 17.5 kV 30.5KV
12/20 kV 24 kV 42 kV
18/30 kV 36 kV 63 kV
21/35 kV 40.5 kV 73.5 kV
26/35 kV 40.5 kV 91 kV

 

  3.6/6 kV XLPE Insulated, Copper conductor, single core, screened, PVC sheathed

 

No. of cores and nominal cross section Operation
voltage
max.
Nominal
voltage
U0/U
Insulation
thickness
Sheath
thickness
Nominal
value
Outer Ø
approx.
weight
approx.
Current ratings in air 30℃ Current ratings buried 20℃ maximum DC resistance at 20℃
mm² kV kV mm mm mm kg / km A A Ω/km
1 x 35 7.2 3.6 / 6 2.5 1.6 18.4 616 205 190 0.52
1 x 50 7.2 3.6 / 6 2.5 1.7 19.9 788 245 225 0.39
1 x 70 7.2 3.6 / 6 2.5 1.7 21 999 305 275 0.27
1 x 95 7.2 3.6 / 6 2.5 1.8 23.5 1276 370 330 0.19
1 x 120 7.2 3.6 / 6 2.5 1.8 24.9 1532 430 375 0.15
1 x 150 7.2 3.6 / 6 2.5 1.9 26.7 1849 490 425 0.12
1 x 185 7.2 3.6 / 6 2.5 1.9 28.3 2197 560 480 0.1
1 x 240 7.2 3.6 / 6 2.6 2.0 30.7 2763 665 555 0.08
1 x 300 7.2 3.6 / 6 2.8 2.1 33.7 3391 765 630 0.06
1 x 400 7.2 3.6 / 6 3.0 2.2 38.9 4433 890 725 0.05
1 x 500 7.2 3.6 / 6 3.2 2.3 42.2 5474 1030 825 0.04
1 x 630 7.2 3.6 / 6 3.2 2.4 45.6 6751 1190 940 0.03

 

  6/10 kV XLPE Insulated, Copper conductor, single core, screened, PVC sheathed

 

No. of cores and nominal cross section Operation
voltage
max.
Nominal
voltage
U0/U
Insulation
thickness
Sheath
thickness
Nominal
value
Outer Ø
approx.
weight
approx.
Current ratings in air 30℃ Current ratings buried 20℃ maximum DC resistance at 20℃
mm² kV kV mm mm mm kg / km A A Ω/km
1 x 35 12 6/ 10 3.4 1.6 20.6 687 205 190 0.52
1 x 50 12 6/ 10 3.4 1.7 22 855 245 225 0.39
1 x 70 12 6/ 10 3.4 1.7 23.6 1086 305 275 0.27
1 x 95 12 6/ 10 3.4 1.8 25.5 1351 370 330 0.19
1 x 120 12 6/ 10 3.4 1.8 26.9 1622 430 375 0.15
1 x 150 12 6/ 10 3.4 1.9 28.6 1932 490 425 0.12
1 x 185 12 6/ 10 3.4 1.9 30.3 2299 560 480 0.1
1 x 240 12 6/ 10 3.4 2.0 32.7 2864 665 555 0.08
1 x 300 12 6/ 10 3.4 2.1 35.3 3459 765 630 0.06
1 x 400 12 6/ 10 3.4 2.2 38.6 4554 890 725 0.05
1 x 500 12 6/ 10 3.4 2.3 42.2 5574 1030 825 0.04
1 x 630 12 6/ 10 3.4 2.4 45.9 6867 1190 940 0.03

 

  8.7/15 kV XLPE Insulated, Copper conductor, single core, screened, PVC sheathed

 

No. of cores and nominal cross section Operation
voltage
max.
Nominal
voltage
U0/U
Insulation
thickness

 
Sheath
thickness
Nominal
value
Outer Ø
approx.
weight
approx.
Current ratings in air 30℃ Current ratings buried 20℃ maximum DC resistance at 20℃
mm² kV kV mm mm mm kg / km A A Ω/km
1 x 35 17.5 8.7 / 15 4.5 1.7 22.9 779 205 190 0.52
1 x 50 17.5 8.7 / 15 4.5 1.7 24.2 952 245 225 0.39
1 x 70 17.5 8.7 / 15 4.5 1.8 26.1 1190 305 275 0.27
1 x 95 17.5 8.7 / 15 4.5 1.9 27.7 1461 370 330 0.19
1 x 120 17.5 8.7 / 15 4.5 1.9 29.3 1738 430 375 0.15
1 x 150 17.5 8.7 / 15 4.5 2 30.9 2054 490 425 0.12
1 x 185 17.5 8.7 / 15 4.5 2 32.7 2427 560 480 0.1
1 x 240 17.5 8.7 / 15 4.5 2.1 35.1 3001 665 555 0.08
1 x 300 17.5 8.7 / 15 4.5 2.2 37.3 3604 765 630 0.06
1 x 400 17.5 8.7 / 15 4.5 2.3 41.9 4702 890 725 0.05
1 x 500 17.5 8.7 / 15 4.5 2.4 45.4 5753 1030 825 0.04
1 x 630 17.5 8.7 / 15 4.5 2.5 49.1 7035 1190 940 0.03

 

  12/20 kV XLPE Insulated, Copper conductor, single core, screened, PVC sheathed

 

No. of cores and nominal cross section Operation
voltage
max.
Nominal
voltage
U0/U
Insulation
thickness
Sheath
thickness
Nominal
value
Outer Ø
approx.
weight
approx.
Current ratings in air 30℃ Current ratings buried 20℃ maximum DC resistance at 20℃
mm² kV kV mm mm mm kg / km A A Ω/km
1 x 35 24 12/ 20 5.5 1.8 24.9 860 205 190 0.52
1 x 50 24 12/ 20 5.5 1.8 26.4 1138 245 225 0.39
1 x 70 24 12/ 20 5.5 1.9 28.1 1281 305 275 0.27
1 x 95 24 12/ 20 5.5 1.9 29.9 1570 370 330 0.19
1 x 120 24 12/ 20 5.5 2 31.3 1839 430 375 0.15
1 x 150 24 12/ 20 5.5 2 33.1 2174 490 425 0.12
1 x 185 24 12/ 20 5.5 2.1 34.7 2540 560 480 0.1
1 x 240 24 12/ 20 5.5 2.2 37.1 3120 665 555 0.08
1 x 300 24 12/ 20 5.5 2.2 39.5 3746 765 630 0.06
1 x 400 24 12/ 20 5.5 2.3 44.1 4863 890 725 0.05
1 x 500 24 12/ 20 5.5 2.4 47.6 5905 1030 825 0.04
1 x 630 24 12/ 20 5.5 2.5 51.3 7220 1190 940 0.03

 

  18/30 kV XLPE Insulated, Copper conductor, single core, screened, PVC sheathed

 

No. of cores and nominal crosssection Operation
voltage
max.
Nominal
voltage
U0/U
Insulation
thickness
Sheath
thickness
Nominal
value
Outer Ø
approx.
weight
approx.
Current ratings in air 30℃ Current ratings buried 20℃ maximum DC resistance at 20℃
mm² kV kV mm mm mm kg / km A A Ω/km
1 x 50 36 18/ 30 8 2 32.6 1363 245 225 0.39
1 x 70 36 18/ 30 8 2 34.3 1614 305 275 0.27
1 x 95 36 18/ 30 8 2.1 36.1 1919 370 330 0.19
1 x 120 36 18/ 30 8 2.1 37.5 2203 430 375 0.15
1 x 150 36 18/ 30 8 2.2 39.3 2556 490 425 0.12
1 x 185 36 18/ 30 8 2.2 40.9 2934 560 480 0.1
1 x 240 36 18/ 30 8 2.3 43.3 3540 665 555 0.08
1 x 300 36 18/ 30 8 2.4 45.7 4191 765 630 0.06
1 x 400 36 18/ 30 8 2.5 49.1 5246 890 725 0.05
1 x 500 36 18/ 30 8 2.6 54.6 6561 1030 825 0.04
1 x 630 36 18/ 30 8 2.7 58.4 7906 1190 940 0.03

 

  21/35 kV XLPE Insulated, Copper conductor, single core, screened, PVC sheathed

 

No. of cores and nominal crosssection Operation
voltage
max.
Nominal
voltage
U0/U
Insulation
thickness
Sheath
thickness
Nominal
value
Outer Ø
approx.
weight
approx.
Current ratings in air 30℃ Current ratings buried 20℃ maximum DC resistance at 20℃
mm² kV kV mm mm mm kg / km A A Ω/km
1 x 50 40.5 21/ 35 9.3 2.1 34.8 1533 245 225 0.39
1 x 70 40.5 21/ 35 9.3 2.1 36.4 1791 305 275 0.27
1 x 95 40.5 21/ 35 9.3 2.2 38.3 2115 370 330 0.19
1 x 120 40.5 21/ 35 9.3 2.2 39.7 2408 430 375 0.15
1 x 150 40.5 21/ 35 9.3 2.3 41.4 2769 490 425 0.12
1 x 185 40.5 21/ 35 9.3 2.3 43.1 3167 560 480 0.1
1 x 240 40.5 21/ 35 9.3 2.4 45.5 3790 665 555 0.08
1 x 300 40.5 21/ 35 9.3 2.5 48.1 4481 765 630 0.06
1 x 400 40.5 21/ 35 9.3 2.6 51.4 5561 890 725 0.05
1 x 500 40.5 21/ 35 9.3 2.7 57.1 6894 1000 825 0.04
1 x 630 40.5 21/ 35 9.3 2.8 60.8 8263 1160 940 0.03

 

  26/35 kV XLPE Insulated, Copper conductor, single core, screened, PVC sheathed

 

No. of cores and nominal crosssection Operation
voltage
max.
Nominal
voltage
U0/U
Insulation
thickness
Sheath
thickness
Nominal
value
Outer Ø
approx.
weight
approx.
Current ratings in air 30℃ Current ratings buried 20℃ maximum DC resistance at 20℃
mm² kV kV mm mm mm kg / km A A Ω/km
1 x 50 40.5 26/ 35 10.5 2.2 37.6 1715 245 225 0.39
1 x 70 40.5 26/ 35 10.5 2.2 39.2 1980 305 275 0.27
1 x 95 40.5 26/ 35 10.5 2.3 41.1 2313 370 330 0.19
1 x 120 40.5 26/ 35 10.5 2.3 42.5 2612 430 375 0.15
1 x 150 40.5 26/ 35 10.5 2.4 44.2 2981 490 425 0.12
1 x 185 40.5 26/ 35 10.5 2.4 45.9 3387 560 480 0.1
1 x 240 40.5 26/ 35 10.5 2.5 48.3 4021 665 555 0.08
1 x 300 40.5 26/ 35 10.5 2.6 50.9 4725 765 630 0.06
1 x 400 40.5 26/ 35 10.5 2.7 54.2 5820 890 725 0.05
1 x 500 40.5 26/ 35 10.5 2.8 59.7 7142 1000 825 0.04
1 x 630 40.5 26/ 35 10.5 2.9 63.4 8528 1160 940 0.03


*Dimensions and specifications may be changed without prior notice.

 

  MEDIUM VOLTAGE CABLE TESTING

 

Routine tests:

Sample tests:  Type tests: 

These non-destructive tests are normally carried out on all lengths manufactured.
- Conductor resistivity
- Spark test on oversheath
- Voltage tests on sheath
- D.C. voltage test on oversheath

These potentially destructive tests are normally carried out on every production run.
- Examination of conductor and dimensions
- Hot set test for XLPE insulation
- Insulation and oversheath thickness
- Four hour voltage test
These destructive tests are normally carried out in addition to the above tests on commencement of a particular cable supply to validate its design.
- Electrical type tests including bending and heat cycle
- Non-electrical type tests including mechanical properties after ageing and tests under fire conditions.

 

  PACKING AND SHIPPING

 

Packing: steel wooden drum, other as required ; standard delivery length is 300 m

 

Packaging details :

Delivery :

XLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KV XLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KV

XLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KV

Steel Wooden Drums Cable Drum In container  shipped in 15 days after payment

 

  Cable Drum Data

 

CABLE DRUMS D1=Flange Diameter(mm) W=Useful Width (mm) D2=Barrel Diameter(mm)
XLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KV 1000 700 500
1100 700 550
1200 700 600
1400 750 710
1600 900 900
1800 1120 1000
2400 1150 1300

 

 

  Delivery Port:

 

XLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KV XLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KV XLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KV
Port of Shenzhen  Port of Hongkong  Port of Guangzhou
 

 

  Our production in numbers

 

XLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KV

● Cable production started 1983
● 35 years of cable manufacturing experience

● Sales in 2016 about 500 million USD

100,000 m2 Production area
● 350 Will-trained employees
● Exported more than 22 countries
● 2 Manufacturing plant
● R&D Center

● 200 Sets Of Testing Equipment

● 100 Testing Items
 8 workshop
● 40 wire drawing machines
● 10 bunching machines
● 28 Extruder system
● 42 stranding machines
● 10 Braiding machines

 
  Shenzhen chengtiantai cable operates certified management systems compliant with:
 
  Certificat Information
XLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KV
ISO 9001:2008
Quality management systems

 

Certificat ISO 9001:2008
- Shenzhen chengtiantai cable industry development Co.Ltd. ;
Certified through Guangdong quality Testing CTC Certification Co.Ltd.;
Valid until 13 January 2019

XLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KV
ISO 14001:2004
Environmental management systems

Certificat ISO 14001:2004

- Shenzhen chengtiantai cable industry development Co.Ltd. ;

Certified through Guangdong quality Testing CTC Certification Co.Ltd.;

Valid until 13 January 2019

XLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KV
OHSAS 18001:2007
Assessment specification for occupational health & safety management systemsenvironmental management systems
Certificat OHSAS 18001:2007
- Shenzhen chengtiantai cable industry development Co.Ltd. ;
Certified through Guangdong quality Testing CTC Certification Co.Ltd.;
Valid until 13 January 2019

 

  Manufacturing Process Of Medium Voltage Power Cable

 
XLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KV XLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KV XLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KV
1. copper rod 2. wire drawing 3. wire stranding
XLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KV XLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KV XLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KV
4. Assembling 5. Triple Extrusion Process 6. Screening Process
XLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KV XLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KV XLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KV
7. outer covering Process 8. Marking 9. cabling
 
  Some great shot on our manufacturing plant
 
Located in: Chengtiantai Industrial Park, Guangming New District, Shen zhen P. R. China 518106
 
XLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KVXLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KVXLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KV XLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KVXLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KVXLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KV
 

  Customer services:

 

XLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KV

  RECOMMENDED ORDERING PARAMETERS

  CONTACT

For prompt quotation / supplies please make sure your inquiries and your orders are
securing the following data :

1 - International or Special Standard. (Alternatively, the precise usage of the cable.)
2 - Rated voltage.
3 - Copper or Aluminium conductors.
4 - Size of each conductor.
5 - Insulation material : XLPE or others.
6 - Number and identification of conductors.
7 - Other requirements.
8 - Packing.
9 - Required delivery time.
10 - Required validity.

If this all seems a litle too technical for you, then why not get in touch with us.

 

We look forward to assisting you in identifying the best products for your specific application and to answer any questions you might have.

 

Tel:+86 755 6114 5028
Fax:+86 755 61137976
E-mail : cttcable@hotmail.com
Head office:chengtiantai Industrial Park, Lisonglang community, Gongming office, Guangming district, Shenzhen P.R. China 518106

 

  WARRANTY

 

For a period commencing on the date shipped the Goods to Buyer and continuing for a period of 12 months thereafter.

Contact Details
Shenzhen Chengtiantai Cable Industry Development Co.,Ltd

Contact Person: Mr. Xie

Tel: +8618682219285

Send your inquiry directly to us (0 / 3000)